Quantitative Analysis , DNA/Protein Testing , Kinetics , Quality Control
Type
Other
Size
635x515x255mm
Dimension (L*W*H)
635x515x255mm Millimeter (mm)
Height
255 mm Millimeter (mm)
Product Type
Spectrophotometer
Weight
26kg Kilograms (kg)
Color
white
Length
515 mm Millimeter (mm)
Width
635 mm Millimeter (mm)
Power
AC 90-250V 50/60Hz
Voltage
AC 90-250V Volt (v)
Application
Ideal for pharmaceutical quality control, environmental monitoring, biochemical research (DNA/RNA/Protein), and industrial QC laboratories.
Warranty
1 Year Warranty
Double Beam UV-VIS Spectrophotometer Trade Information
Minimum Order Quantity
1 Unit
Payment Terms
Cash in Advance (CID)
Supply Ability
05 Units Per Month
Delivery Time
2 Week
Packaging Details
wooden Packaging
Main Export Market(s)
Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
Main Domestic Market
All India
About Double Beam UV-VIS Spectrophotometer
The Lasany Microprocessor UV-VIS Double Beam Spectrophotometer (LI-2802 R) is a high-precision analytical instrument designed for quantitative and qualitative laboratory analysis. It utilizes a double-beam optical system to simultaneously measure sample and reference beams, which compensates for light source fluctuations and ensures long-term stability
Key Features
Double Beam Optics: Features a blazed holographic grating (1200 lines/mm) and dual silicon photodiode detectors for enhanced accuracy and reduced drift.
Sample Handling: Equipped with an automatic 8-cell holder for 10mm pathlength cuvettes, significantly increasing sample throughput.
Operating Modes: Supports diverse measurement methods including Basic Mode, Quantitative (standard curve), Kinetics, Multi-wavelength, Wavelength Scan, and DNA/Protein testing.
Automated Calibration: Features automatic wavelength calibration, system self-testing, and automatic lamp change-over between Deuterium and Tungsten lamps.
21 CFR Part 11 Software (Optional): While standard software is included, compliance software for pharmaceutical GLP/GMP requirements (21 CFR Part 11) is available at an extra cost to provide electronic audit trails and secure user access.
Applications: Ideal for pharmaceutical quality control, environmental monitoring, biochemical research (DNA/RNA/Protein), and industrial QC laboratories.
Precision and High-Resolution Performance
Achieve exceptional reliability and accuracy in your measurements with the double-beam optics and an impressive 0.5 nm wavelength accuracy. The 1 nm bandwidth ensures detection of even the smallest changes in sample absorbance, which is essential for detailed analyses in quality control and research environments.
Versatile and User-Friendly Design
This spectrophotometer is engineered for both efficiency and flexibility. The automatic 8-cell holder allows for high-throughput testing, while the interface is straightforward for daily use. Multiple speed settings accommodate various analytical needs, from DNA/protein quantification to kinetic studies.
Optimal for Laboratory Applications
Its robust construction and comprehensive features make the instrument suitable for a spectrum of applications, including pharmaceutical QC, environmental monitoring, biochemical assays (DNA/RNA/protein), and industrial quality control, ensuring broad utility in professional Indian laboratories.
FAQ's of Double Beam UV-VIS Spectrophotometer:
Q: How does the double-beam optics system benefit laboratory analyses?
A: The double-beam optics system improves accuracy by simultaneously measuring both the sample and the reference, compensating for fluctuations in light source and detector, and reducing baseline drift. This results in more reliable and precise data for critical analyses.
Q: What types of samples and applications is this spectrophotometer suited for?
A: This device is ideal for quantitative analysis, DNA and protein testing, kinetic studies, and quality control. It's particularly beneficial in pharmaceutical QC, biochemical research, environmental monitoring, and industrial laboratories due to its high resolution and versatile functionality.
Q: When should I consider using the high-speed scanning mode?
A: High-speed mode, reaching up to 2000 nm/min, should be used when rapid spectral acquisition is required, such as during kinetic studies or when analyzing multiple samples quickly without compromising data integrity.
Q: Where can this spectrophotometer be installed?
A: Its compact rectangle shape and manageable weight (26 kg) make it suitable for installation in a variety of laboratory settings, including academic research labs, pharmaceutical QC facilities, industrial QC departments, and biochemical analysis units across India.
Q: What is the process for using the automatic 8-cell holder?
A: The automatic 8-cell holder allows users to load multiple samples simultaneously. The device automatically positions each cell for sequential measurement, increasing efficiency and throughput, especially in high-volume laboratory environments.
Q: What are the key benefits of its 1 nm bandwidth and 0.5 nm wavelength accuracy?
A: A 1 nm bandwidth ensures fine resolution to differentiate overlapping spectral peaks. The 0.5 nm wavelength accuracy enables precise identification and quantification of analytes, crucial for rigorous research work and regulatory compliance.
Tell us about your requirement
Price:
Quantity
Select Unit
50
100
200
250
500
1000+
Additional detail
Mobile number
Email
Name
Comapny Name
Phone Number
Email Id
City / State
Confirm Your Requirement
Verification Code
Did not receive yet?
Resend OTP
You’re Done!
We have received your requirements and will reply shortly with the best price.